Without Steam
Saturated Steam
Superheated Steam
Comparison of Steam Injected Stove Technology
Steam Injection Method | Flame color | Burning Rate (kg/hr-m2) | Steam Consumption (lph) | Fuel to Steam Ratio | Thermal Eficency (%) | Power Output (kW) |
Without Steam | Yelow with red | 52.17 | - | - | 7.8 | 0.93 |
Saturate Steam | Yelow to orange | 54.0-71.9 | 1.23-1.35 | 2.8-3.4 | 7.8-9.0 | 0.97-1.49 |
Super Heated Steam | Pink to yelow | 43.9-53.1 | 1.25-1.4 | 2.24-2.56 | 10-112.0 | 1.2-1.35 |